ELRE

Whole house ventilation in a villa: an architect's guide to ducts, silence and filters

Whole house ventilation: solutions, ducts, silence and upkeep, explained by architects.

Whole house ventilation in a villa: why it is designed and how

Whole house ventilation is the system that renews the air of the home without opening the windows. In a well-insulated villa with airtight windows it is almost always necessary: the more closed the house, the less the air renews itself, and without designed air change, damp, odours and mould appear. Good whole house ventilation is not noticed; badly done, it is heard, seen and switched off after a month.

Most pages that Google shows for this search are product sheets and generic guides. We explain, as architects, where the ducts run, how to protect silence, what the European regulations say about ventilation units and how whole house ventilation is coordinated with the heat pump, the fireplace and the cooker hood. We do not sell systems, we do not cite brands and we do not give prices or flow rates, which depend on the design.

Whole house ventilation at a glance

  • Why it is needed: in an airtight house the air does not renew itself, and humidity builds up.
  • Heat recovery reduces the energy lost with the exhaust air.
  • The ducts are an architectural problem: ceilings, heights, grilles.
  • Silence is designed: the European regulation sets sound power limits for the units.
  • Maintenance of the filters must be easy, or the system stops working.
Interiors of MD Home in Verona, a studio project
The pool area of SD Home in Soave

The Villa Edit
Materials and systems of the villa

Underfloor heating
The guide

External wall insulation
The guide

Air source heat pump
The guide

Modern fireplace
The guide

Preliminary reading
Understand a villa before you buy it

Signature Architecture
Design or renovate a villa

Contact
Write to us

Private Service

Private Consultation

Planning a villa?

Contact us

Why an airtight house needs ventilation

A modern villa has insulated walls, high-quality windows and few air leaks. It is a virtue for energy use, but the indoor air no longer renews itself: the people living in the house produce vapour, carbon dioxide and substances that materials release.

The integrated text of the minimum-requirements decree, updated in 2025, lists among its general criteria thermo-hygrometric wellbeing and indoor air quality: air change is part of the energy design, not an accessory. The integrated text we quote is not the official version: for a real application you work from the decree in the Gazette with your energy engineer.

Whole house ventilation links with other works. Where the envelope is improved with external wall insulation, the house becomes more closed: if air change is not planned, the risk of condensation and mould rises. That is why whole house ventilation must be thought of in the same project, not as a remedy after problems appear.

Full-height glazing onto a terrace with plants, a studio project

The solutions: central, single room, extract-only

There are four solutions for whole house ventilation, summarised in the table:

SolutionHow it worksWhat to check
Central balanced systemOne unit with ducts through the house extracts and supplies air while recovering heatSpace for ducts and unit, noise, filter maintenance
Decentralised (single room) unitsSmall units in the walls, no ductsLook of the grilles on the facade, noise, number of units
Extract-onlyExtracts stale air and lets fresh air in through vents in the windowsLoses the heat of the exhaust air, vents on the facade
With dehumidificationAdds humidity control in a spa, pool or cellarCondensate, drainage, dedicated system

In a new villa the best solution is almost always the central balanced system: one unit, hidden ducts, outlets flush with the ceiling. In a renovation with no room for ducts, decentralised units are a middle way, with the limit of grilles on the facade. Extract-only ventilation is the simplest and the least efficient in energy terms, because it throws out warm air without recovering it.

Explore our projects

Metra glazing, Viabizzuno and OTY lighting, infinity pool: design and site direction by the studio.

What the European regulation says

Ventilation units are regulated by Regulation (EU) No 1253/2014 on ecodesign. The text distinguishes residential units, with a maximum flow of up to 250 cubic metres per hour, or up to 1,000 if the manufacturer declares them for residential buildings only, from non-residential ones. For residential units the regulation requires multi-speed or variable-speed control, and for bidirectional units, those that both extract and supply air, a compulsory thermal bypass.

On noise, the regulation sets a maximum sound power level for residential units that are not ducted: 45 dB from 2016 and 40 dB from 2018. From 2018 a visual signal is also required to warn when to replace the filter. These are minimum requirements to enter the European market: they do not say the system will be silent in a bedroom, because perceived noise depends on ducts, grilles, speed and the room.

Where the ducts run: the architectural problem

A central whole house ventilation system needs ducts, and ducts have a cross-section. In an ordinary floor they run in the ceiling void of corridors and bathrooms, where height allows; they do not pass through beams and do not cross floors easily. That is why the design of the system is born together with the building sections: internal heights, ceiling voids, vertical shafts, technical room.

We draw the ducts on the sections before fixing the heights: so a corridor with a ceiling at 2.40 metres does not become a problem when it turns out the duct is needed. Outlets are chosen flush with the ceiling or as slots, in the same material as the finishes, and diffusers are laid out so the air does not blow on whoever sleeps or sits in the living room.

Interiors of MD Home in Verona, a studio project
Interiors of SD Home in Soave, a studio project

Invest

Underfloor heating explained by architects: systems, temperatures, heat pumps, suitable floors…

Explore our projects

Schüco glazing, Minimal Cucine and Modulnova kitchen, Poliform and Baxter furniture, Occhio lighting, MAFI wood.

Silence: the real test of ventilation

Whole house ventilation that can be heard in the bedroom gets switched off. To avoid it, what counts is the air speed in the ducts, the length of the runs, silencers, mounting the unit on anti-vibration supports and placing the technical room away from the bedrooms. The European sound power limit is a starting point, and the real test is the finished system, measured with the room closed and the ventilation at its planned speed.

Ask the designer how the system behaves at the lowest speed, the one you will use at night: whole house ventilation should run continuously and almost imperceptibly. The higher speed is used when cooking, for guests or after a shower, not as normal operation.

Heat recovery, bypass and winter

Heat recovery is the reason balanced whole house ventilation uses less energy than opening windows: the air going out gives its heat to the air coming in. The European regulation requires a thermal bypass for bidirectional units, which in summer lets air in without passing through the exchanger. We do not write recovery percentages, because they vary by model and conditions and must be read in the data sheet with the test conditions.

With the air source heat pump whole house ventilation works well: the incoming air is already preheated, the system load falls and the house keeps temperature and humidity steadier. With a low-temperature system such as underfloor heating, the whole gives the comfort people now expect from a villa.

Glazing with light curtains onto the garden, a studio project

Explore our projects

Edra sofas, Varenna kitchen, Noorth and Agape bathrooms: a studio project.

Fireplace, cooker hood and negative pressure

Balanced whole house ventilation supplies as much air as it extracts. An open fireplace or a cooker hood that extracts a lot of air breaks this balance and can create negative pressure in the house, with smoke returning from the fireplace. That is why, in a villa with a modern fireplace, the design of the ventilation and of the fireplace are coordinated: a dedicated air intake, a sealed firebox and a hood with make-up air.

The same applies to the kitchen: the hood must not be connected to the ventilation ducts, because grease and moisture soil them. A separate exhaust is planned, with a compensating air intake, and the whole house ventilation renews the air of the home the rest of the time.

A room at MD Home with natural light
A window wall at MD Home in Verona

Invest

External wall insulation for a villa in Italy, explained by architects: outside or inside…

Humidity, spa and gym

Rooms with a lot of humidity, such as a spa, a steam room or a home gym, need more than general ventilation: they need dedicated extraction and, for an indoor pool, dehumidification. If humidity is not controlled, finishes, windows and structures degrade. The whole house ventilation system does not have to be sized for these rooms, but it must coexist with their dedicated system.

A good practice is to separate the circuits: air of the house and air of the humid rooms. That way the humidity of the spa does not enter the bedrooms, and the filters of the whole house ventilation stay clean longer.

Filters and maintenance

Whole house ventilation works as long as the filters are clean. The European regulation introduced from 2018 the visual signal that warns when to change them, but the signal is useful only if someone acts. The technical room must allow the unit to be opened and the filters replaced without dismantling anything; ducts must have inspection hatches; the maintenance contract should be planned from the start.

In the villas we manage we advise writing the maintenance instructions of the whole house ventilation into the house manual, with the frequency of checks and the filter codes. It is a detail nobody asks for and that makes the difference after five years.

Open plan living area with full-height glazing, a studio project

Invest

Air source heat pump for a villa in Italy, explained by architects: types, envelope, underfloor…

Commissioning and fine-tuning

Whole house ventilation is not finished when the contractor dismantles the site: it must be fine-tuned. Commissioning includes measuring the flow at every outlet, balancing supplied and extracted air, checking noise with the room closed and testing the control devices. An outlet that supplies too much air makes a bedroom unpleasant; one that supplies too little leaves it stale. The site supervisor must have a commissioning report with the measured values, to keep with the house manual.

After the first year it is worth repeating the check: the filters have loaded, the family’s habits have emerged, the rooms are used differently from the plan. Adjusting the speeds to real use costs little and improves comfort. Whole house ventilation is learned like a house: with a few weeks of attention and without changing the settings at random.

Whole house ventilation in our projects

A clarification: the photos in this guide show exteriors and interiors of the studio’s projects, and none documents a ventilation system. We chose them because they show how spaces, windows and light are conceived together, which is where the air design starts too. For related topics see our guides to external wall insulation and the air source heat pump.

Invest

Before buying a luxury villa in Italy, the Dominican Republic, Zanzibar or Dubai: send us the…

Glazing with light curtains onto the garden, a studio project

How much does whole house ventilation cost?

We do not give figures, because they depend on the unit, ducts, number of outlets, technical room and the building work for the ceilings. The real cost of whole house ventilation depends on five items: unit and heat recovery, ducting and silencers, outlets and diffusers, building work and ceilings, control and commissioning. Ask for quotes that separate them.

The advice is to plan it at design stage, when ducts run in the ceilings without extra works: in a finished house the cost grows, because walls are opened and finishes redone. Incentives change often: check them with your technician and accountant at the time of the application.

Whole house ventilation: checklist before you sign

  1. Is the space for the ducts of the whole house ventilation in the sections?
  2. Where is the technical room of the whole house ventilation?
  3. How quiet is the whole house ventilation at its night-time speed?
  4. How are whole house ventilation, fireplace and hood coordinated?
  5. Who changes the filters of the whole house ventilation?
  6. Does the quote for the whole house ventilation separate unit, ducts, outlets and building work?
Bright living room with large sliding windows, a studio project

Invest

Modern fireplace explained by architects: where to place it, wood, pellet, gas or bioethanol, EU…

Whole house ventilation: ten mistakes to avoid

  1. Thinking of it after the design, when there is no room left for ducts.
  2. Choosing the unit on flow rate alone, without assessing noise and filters.
  3. Placing the technical room next to the bedrooms.
  4. Connecting the cooker hood to the ventilation ducts.
  5. Ignoring the balance with fireplace and hood.
  6. Forgetting the inspection hatches.
  7. Not planning filter maintenance.
  8. Treating the spa like any bathroom.
  9. Leaving the ventilation at high speed all year.
  10. Comparing quotes without separating unit, ducts, outlets and building work.

Whole house ventilation: frequently asked questions

What is whole house ventilation?

It is a system that renews the air of the home continuously and in a controlled way, with fans and ducts, often recovering the heat of the exhaust air.

Almost always: in an airtight house the air does not renew itself, and without designed air change humidity, odours and the risk of mould increase.

Regulation 1253/2014 sets requirements for ventilation units: multi-speed control, thermal bypass for bidirectional units, a sound power limit and, from 2018, a filter replacement signal.

It depends on design and speed. The regulation limits the sound power of the units, but perceived noise depends on ducts, grilles and the technical room.

In the ceiling voids of corridors and bathrooms and in vertical shafts, planned in the design of the sections.

Yes, but it is coordinated: sealed firebox, dedicated air intake and a hood with make-up air, to avoid negative pressure in the house.

It depends on unit, ducts, outlets, building work and commissioning. Ask for separate quotes for these items.

Architecture

Luxury interiors for villas: the 12 systems of The Villa Edit, from passive house to furniture…

Architecture

UHNW luxury villa architecture designed and supervised by Federico Cappellina’s studio since 2002…

Pool Villas in Colognola ai Colli, a studio project

Whole house ventilation: in conclusion

In a villa, whole house ventilation is a matter of architecture before technology. Whole house ventilation works when the design has provided space for ducts and unit, when silence has been checked and when filter maintenance is simple. That is why whole house ventilation is decided together with the envelope, the systems and the finishes, not afterwards.

Whoever designs or renovates a villa should ask from the start what the whole house ventilation will look like, where the ducts will run and who will maintain it over time: the three questions that separate a system you forget about from one you switch off.

Designing or renovating a villa in Italy?

Send us the plan: we tell you where the ducts can run, where to put the technical room and what to have checked by the energy engineer and the acoustic designer. For a complete project see Signature Architecture or write to us from Contact.

Sources: Regulation (EU) No 1253/2014, ecodesign requirements for ventilation units; integrated (unofficial) text of the Italian DM of 26 June 2015 as updated by the DM of 28 October 2025. Checked on 8 November 2026. Photos: projects by Federico Cappellina Architects, which do not show a ventilation system.

Would you like an opinion on the project?

Send us the plan: we reply with the points to verify.

Discover the UHNW Lifestyle